Volume & Issue no: Volume 6, Issue 5, May 2017
_____________________________________________________________________________
Title: |
BEHAVIOUR OF COMPOSITE STRUCTURE OF RCC AND FLYASH BRICK MASONRY |
Author Name: |
SweetaMohanty, Dr.B.Jena |
Abstract: |
ABSTRACT
An attempt is made to prevent shear failure in composite structure of RCC lintel and flyash brick masonry above it. Hear we
consider RCC lintel and the flyash brick masonry altogether as a composite structure. In a wall openings with the lintel beam
and masonry above, the two components act together in supporting the load. The composite action of lintel with masonry above
is a complex phenomenon. RCC Lintel specimen of spanning 1.5 meter were constructed with the depth of 101.6 mm (4
inches) and a width of 228.6 mm (9 inches). The reinforced bars of 8mm diameter (4 nos.) were cut and tied with distribution
bas of 6mm diameter (8 nos.) with the help of G.I. wires. In addition, 3nos. of concrete cube of size 150mm×150mm×150mm
were tested and the compressive strength is calculated, relating to the RCC lintel-beam. Three specimens of RCC lintel (of same
cross section) and brick masonry above it were tested, from that thespecimens were cast with masonry above the lintel up to
three, six and nine layers in English bond of flyash brick masonry. This lintel-masonry walls were tested to failure under two
point load and their load deflection curve was plotted. And the comparative study of theoretical and experimental shear
strength has been done.
Index Terms: composite structure, flyash brick masonry, shear failure, RCC lintel, load deflection curve, bending
moment and shear force diagram |
Cite this article: |
SweetaMohanty, Dr.B.Jena , "
BEHAVIOUR OF COMPOSITE STRUCTURE OF RCC AND FLYASH BRICK MASONRY " , International Journal of Application or Innovation in Engineering & Management (IJAIEM) ,
Volume 6, Issue 5, May 2017 , pp.
173-190 , ISSN 2319 - 4847.
|